Fan Bearing Overheat, Damage and Treatment Measures

Fan Bearing Overheat, Damage and Treatment Measures Usually the fan bearing temperature should not exceed 70 ℃, but in fact there are overheating conditions above this temperature. In order to solve this kind of problem, the following is to explain the different causes of overheating: Usually the fan bearing temperature should not exceed 70 ℃, but in fact there are overheating conditions above this temperature. In order to solve this kind of problem, the following is to explain the different causes of overheating: 1. Insufficient oil quantity, for which the following measures can be taken 1) When there are uneven levels in the oil pipeline, air should be fully extracted. 2) After the oil cooler is dirty, the cooling effect will be reduced, resulting in insufficient cooling oil. The cooler should be cleaned in time. 3) When the filter element is dirty, the element should be replaced. 4) When using oil ring bearings, use an oil level gauge to detect the oil level and observe whether the oil ring is running normally from the observation window. 5) In rolling bearings, overheating occurs due to insufficient grease or excessive filling. When adding grease, it is better to wipe off the original grease and replace it with a new one. Its dosage is suitable for nearly 2/3 of the space of the fan bearing box. 2. Poor oil quality selection When the oil quality does not meet the requirements or the quality is changed, it is also one of the reasons for overheating. The oil quality recommended by the fan manufacturer should be used. When changing the oil quality, it needs to be carefully studied before it can be used. In addition, the replacement standard of oil should be based on the degree of oxidation, viscosity, viscosity index, dirt degree, etc., and it is appropriate to formulate a rough standard.

09-25

2020

Anti-surge Measures of Centrifugal Fan

Centrifugal fan anti-surge measures: 1) The selection of centrifugal fan should be in the effective area. Do not artificially arbitrarily increase the selection coefficient, so that the fan in operation, the actual fan flow is much higher than the design fan flow. When using a large number of throttling, it is easy to adjust the fan to work in the surge area. Therefore, in the design and selection of the fan, it is necessary to avoid the working condition range approaching the surge zone. If the box-type fan surges, check whether the air duct interface is deformed. 2) Once the centrifugal fan surges during system operation, the operating range of the working condition can be adjusted by changing the rotating speed of the fan, and the installation angle of the moving blade can also be changed. These methods can move the performance curve of the fan to the small flow area, and then the surge critical line also moves to the small flow area accordingly, thus expanding the stable operating range of the fan. 3) Because some workplaces do not have the above adjustment conditions, can not stop the production, but there is a simple and quick adjustment method can eliminate the surge, is to add a bleed valve. Make qv = qv and put qv surge> qvmin, and the surge can be eliminated immediately. It is pointed out that the gas put into the atmosphere should be harmless, and if it is harmful, it should be introduced into the inlet pipe of the ventilator by a small pipe.

09-25

2020

< 1 > proceed page